Nik DICOM ViewerCT · MR · PET · RT

Files stay on this computer.
Drop a DICOM folder, files or an archive (ZIP, 7z, RAR, TAR…)

About Nik DICOM Viewer

Created by Dr Nikolay Nedev, MD, FRANZCR, FC Rad Onc (SA).

Not for clinical use. This software is intended for education, research and personal review of images only. It is not a medical device: it has not been cleared or approved by the US Food and Drug Administration (FDA), nor CE-marked under the EU Medical Device Regulation, and it must not be used for diagnosis, treatment planning or any other clinical decision.

It is provided “as is”, without warranties of any kind, express or implied, including fitness for a particular purpose. The author accepts no liability for any loss or harm arising from its use. Values it shows (HU, SUV, dose, volumes, DVH) may differ from those of certified clinical systems.

The viewer is free and is intended to remain free. If you find it useful and would like to support the work, you can buy me a coffee — or two.

☕ Buy me a coffee buymeacoffee.com/nikolaynedev

nikdicom.com · Third-party licences

Shortcuts

Scroll slicesMouse wheel, ↑ ↓, PgUp PgDn, Home End
Active toolLeft drag · W window, P pan, Z zoom, L length, E ellipse
Zoom · panRight drag or Ctrl + wheel · middle drag or Shift + drag; pinch on touch
Window presets1–7 (CT and PET); 0 back to the file's window
Invert · reset · cineI · R · Space
Sphere VOI (SUVmax)S, then click the lesion centre and drag out the radius. Works in a PET viewport or a fused one.
RTRT button (header) opens the RT tab: load RTSTRUCT / RTDOSE / RTPLAN files for the patient on screen, show or hide structures, isodose lines or colour wash with your reference dose, and the plan's prescription and beams.
DVHIn the RT tab: DVH… computes cumulative dose–volume histograms for every structure from the linked dose (3D, sampled inside each contour on a fine grid; each contoured slice counts for one slice spacing, as for the volumes). The table gives Dmin/Dmean/Dmax, D98/D95/D50/D2 and V95/V100 of the 100% dose; Copy table copies it for a report.
ContouringD pencil: draw a closed outline on an axial (acquired-plane) slice; it is added to the structure selected in the panel. Interpolate (next to Pencil) fills the skipped slices between drawn ones, for all your structures. Each contour has a label: click its name to rename the structure, or × to delete that contour; Ctrl+Z undoes the last stroke, Esc cancels one in progress, Clear marks removes all pencil contours. Contours show in coronal and sagittal MPR.
LocatorC, then click or drag on a point: every view of the same patient moves to that point and shows a yellow crosshair with the value there. Esc clears it.
MPRMPR button: axial · coronal · sagittal of the active series. Per viewport: plane, slab thickness (mm) and Average / MIP / MinIP. Double-click a point to bring the other views to it.
Fusion on/offF in the active viewport
Next viewport · seriesTab · [ ]
Delete a markClick the × on its label · Delete or Ctrl+Z removes the last one · Shift+Delete all on the slice · Clear marks everything on the series

A study sent as an archive (for example via WeTransfer) opens directly with unZIP or by dropping it on the window: ZIP, 7z, RAR (v4 and v5), TAR, TAR.GZ/TGZ, GZ, BZ2, XZ and ISO disc images. Everything is unpacked in memory; nothing is written to disk. ZIP, TAR and GZ use the browser's own decompression; the others use a bundled libarchive decoder (WebAssembly), loaded only when needed. Password-protected and multi-part (split) archives are not supported.

Put a series in a viewport by clicking it in the list (goes to the active viewport) or dragging it onto any viewport. With Link on, viewports in the same patient space scroll, zoom and point together. SUV is body-weight SUV, computed from the PET header (decay corrected to series time). In the sphere VOI, SUVpeak is the highest mean SUV in a 1 cm³ sphere (radius 6.2 mm) centred on one of the 50 hottest voxels inside the VOI; MTV counts voxels at or above 41% of SUVmax; TLG = MTV × their mean SUV. Voxels count when their centre lies inside the sphere. MPR resamples the series volume with trilinear interpolation; a large CT (500+ slices) needs about 4 bytes per voxel of memory.

Open a CD or DVD

Insert the disc, then choose the drive itself (for example D: on Windows, or the disc under Locations on a Mac) in the folder picker.

The browser will ask whether to “upload” the files. Nothing leaves your computer: the files are only read here. If the disc has a DICOMDIR index, it is used, so only the images you open are read from the disc. The disc's own viewer program is ignored.

Dose–volume histogram

Patients